Airflow UV purification device
Airlia compact
Removes bacteria and viruses with the power of light
The strong ultraviolet rays disinfect the indoor air.
Ultraviolet disinfection acts directly on the DNA and RNA that control cells to inactivate them, so this method is expected to be effective even when bacteria or viruses are mutated.
Characteristics
- Up to 99% UV disinfection performance*
- Safe enclosed UV design
- Chemical-free operation
- No filter maintenance required
- Long-life UV lamp
- Low maintenance requirements
*Based on third-party testing under specified conditions.
Applications
- Hospitals & Healthcare Facilities
- Food Processing Plants
- Restaurants & Commercial Kitchens
- Schools & Cafeterias
- Electronics Manufacturing Facilities
- Cleanrooms
- Hotels & Hospitality Facilities
- Sports & Fitness Centers
- Offices & Commercial Buildings
Case studies
- Sakuragawa City Iwase Stadium (RASUKA)

- Toyama Airport Terminal Building

- Boatpier Yokohama

- Komono Town

Airlia compact: Specifications

Coverage guide (for Unit selection)
1 unit: up to 66 m³
*Reference capacity based on reducing Bacillus subtilis to 1/100 after 12 hours under controlled test conditions. Actual results may vary.
- Model
- FZST15201GL15/16, FZST15202GL15/16
- Production type
- Made-to-Order
- Application
- Disinfection of airborne bacteria
- Sterilization method
- UV light + fan ventilation system
- Voltage
- 100V
- Frequency
- 50/60Hz
- Power consumption
- FZST15201GL15/16: 53.1W(50Hz), 45.2W(60Hz)
FZST15202GL15/16: 43.1W(50Hz), 36.3W(60Hz) - Airflow
- 1.1m³/min
- Compatible lamps
- GL15 x 2
- Material
- Steel
- Weight
- 9.6kg
- Power cord length
- Approx. 1.7m (with Plug)
*Two models are available with different fan components, but their performance is identical.
Compatible lamps: specifications
- Model
- GL15
- Lamp output
- 15W
- Tube diameter
- ø25.5mm
- Total length
- 436mm
- Emission length
- 348mm
- Lamp current
- 0.3A
- Lamp life
- 8000h
- Cap
- Pin type
Circulation Test Data
Kitasato Research Center for Environmental Science (Japan) (Report number: 北生発 26_0309)
Test Description
- Test chamber volume: 25 m³
- Test microorganism: Bacillus subtilis spores (ATCC 6633)
- Airborne microorganisms were dispersed inside the chamber and sampled at predetermined time intervals.
- Microbial counts were measured and compared over time during operation of the unit.
Airborne Bacteria Number (CFU/50 L-air) for Each Elapsed Time
| Test conditions | Hours (minutes) | |||||
|---|---|---|---|---|---|---|
| 0 | 30 | 60 | 90 | 120 | 180 | |
| Natural attenuation (control) | 41000 | 22000 | 48000 | 26000 | 58000 | 17000 |
| Air circulation type ultraviolet ray air purifier (15W 2 lamps) | 22000 | 22000 | 4900 | 2800 | 1200 | 150 |
Rate of decrease in the number of bacteria per elapsed time
- * The vertical axis is a logarithmic display.
Ex)
Vertical axis 5=10⁵=100000
Vertical axis 2=10²=100 - * This data is from an equivalent product: Sideways ceiling mount type “Airlia Ceiling (FZS15202GL15/16)”
Handling / Usage Precautions
- This product is not a medical device.
- The actual disinfection or purification effects can change depending on the condition or the use of the room.
- The UV (disinfection) lamp contains a very small amount of mercury. Please be careful when handling the glass, and dispose according to each communities' collection categorization rules.
- Please note that the device's fan will emit a sound, so be careful when using it in quiet areas such as libraries and museums.
- Never look directly or indirectly at the lamp while it is illuminated. Avoid exposure to reflected UV light as well. Failure to do so may result in eye pain or visual impairment.
- Do not expose skin directly or indirectly to UV radiation. Doing so may cause skin inflammation or irritation.
- Always switch off the power before replacing the lamp or performing maintenance. Failure to do so may result in electric shock, eye pain, visual impairment, or skin inflammation.
- If smoke, an unusual odor, or any abnormal condition occurs, immediately switch off the power and contact your installer or the nearest sales office.
- Dust and dirt on the lamp or the reflector surfaces will reduce disinfection performance. Clean them with a soft cloth lightly moistened with a diluted neutral detergent, then wipe dry with a clean cloth to remove any detergent residue.
- Do not modify or disassemble the unit. Doing so may result in fire or electric shock.
- Do not wash the unit with water during maintenance or cleaning. Doing so may result in fire or electric shock.
- This product is designed for indoor use only. Do not use it outdoors or in locations exposed to water or excessive moisture. Failure to do so may result in electric shock due to insulation failure.
- Do not insert metal objects or flammable materials into any openings of the unit. Doing so may result in fire or electric shock.
Contact
For UV sterilization solutions, trust Iwasaki Electric.
We develop custom solutions tailored to your needs.